Grass Valley Kaleido Remote Control Protocol Gateway May.2011 User Manual
Page 17

USER’S GUIDE
Kaleido Remote Control Protocol (Gateway) | 13
setKUnlatch
KX
This command is used to acknowledge the global alarm for a given source (channel). It can also
be used to acknowledge specific alarms.
The command supports three parameter types: channelName, id or uri:
o If channelName is specified, the global alarm associated with the specified source
(channel) will be acknowledged.
o If uri is specified, the alarm with the specified URI will be acknowledged.
o If id is specified then the gateway alarm with the specified ID will be acknowledged.
Note: Only one parameter can be specified, otherwise the Gateway will return
Gateway response:
Examples:
o
o
uri="miranda.monako.daq://local/data/master/3/card/av1/DTVCCData#dt
vccService1Presence"
o
setKChannel
KX K2 AQ
This command is used to assign a logical source (channel) to the specified monitor in the current
layout.
Where:
o ChannelName is the name of the logical source you wish to assign to the specified
monitor. On a Kaleido-X series multi-viewer this is the full path to the source (channel).
Ex.: /Input A/Channel 1.
o MonitorNumber is the identifier of the monitor to which the source is to be assigned.
On a Kaleido-X series multi-viewer the monitor number must be prefixed with the room
name and a ―/‖ if the session does not have a room context. Ex.: