beautypg.com

Grass Valley Kaleido Remote Control Protocol Gateway May.2011 User Manual

Page 17

background image

USER’S GUIDE

Kaleido Remote Control Protocol (Gateway) | 13

setKUnlatch

KX

This command is used to acknowledge the global alarm for a given source (channel). It can also
be used to acknowledge specific alarms.

The command supports three parameter types: channelName, id or uri:

o If channelName is specified, the global alarm associated with the specified source

(channel) will be acknowledged.

o If uri is specified, the alarm with the specified URI will be acknowledged.

o If id is specified then the gateway alarm with the specified ID will be acknowledged.

Note: Only one parameter can be specified, otherwise the Gateway will return .

set channelName="ChannelName"

set uri="AlarmURI"

set id="AlarmName"

Gateway response:

: The command was recognized by the Gateway.

: The Gateway was not able to recognize the command.

Examples:

o set channelName="/Input A/Channel 01"

o set

uri="miranda.monako.daq://local/data/master/3/card/av1/DTVCCData#dt
vccService1Presence"

o set id="my_gateway_alarm_1"

setKChannel

KX K2 AQ

This command is used to assign a logical source (channel) to the specified monitor in the current
layout.

set channelname=ChannelName monitor=MonitorNumber

Where:

o ChannelName is the name of the logical source you wish to assign to the specified

monitor. On a Kaleido-X series multi-viewer this is the full path to the source (channel).
Ex.: /Input A/Channel 1.

o MonitorNumber is the identifier of the monitor to which the source is to be assigned.

On a Kaleido-X series multi-viewer the monitor number must be prefixed with the room
name and a ―/‖ if the session does not have a room context. Ex.: