12 | Kaleido Remote Control Protocol (Gateway)

getKRoomList

KX

This command is used to obtain the list of rooms known to your multi-viewer system.

Gateway response:

Room ARoom B

: The Gateway was not able to recognize the command.

setKStatusMessage

KX K2 AQ

This command associates an Alarm state with an ID. The Kaleido can be configured to listen to
alarm status messages from the Gateway, and thus report the state it receives. This is a
convenient way of reporting Alarms to the Kaleido.

set id="ID" status="Status"
message="Message"

Where:

o ID is the identifier that will receive the new state.

Note: Kaleido-Alto/Quad/Quad-Dual will only accept numeric values for this parameter,
in the range 0 to 1024. The Kaleido-K2 and Kaleido-X series do not have this limitation.

o Status is any of the available statuses:

Status

Alternate (legacy)
status

Kaleido-X Series

Kaleido-K2/Alto/Quad/Quad-Dual

DISABLE

DISABLE

Disabled

Disabled

NORMAL

OK

Normal

OK

MINOR

WARNING

Minor

Warning

MAJOR

MAJOR

Major

(not supported)

CRITICAL

ERROR

Critical

Error

o TheMessage is reserved for future use, and is ignored.

Gateway response:

: The command was recognized by the Gateway.

: The Gateway was not able to recognize the command.