Grass Valley 8900 Frames Gecko 2009 User Manual
Page 54

54
Gecko Frames — Instruction Manual
Section 5 — Specifications
Operating Conditions
Input voltage range
100 V to 240 VAC, 47 Hz to 63 Hz
Maximum input current
1.5 A
Operating temperature range
0 to 45 degrees C
Non-operating temperature range
-10 to +70 degrees C
Humidity
Up to 95% non-condensing
Mechanical
Height
2 RU, 3.5 inches (89 mm)
Width
19 inches (483 mm)
Depth
13.25 inches (337 mm)
Weight with no modules, 1 power supply
TX frame: 18.55 lbs (8.4 kg)
TF frame: 19.2 lbs (8.7 kg)
TFN frame: 20.2 lbs (9.16 kg)
Weight with no modules, 2 power supplies
TX frame: 19.75 lbs (8.96 kg)
TF frame: 20.4 lbs (9.2 kg)
TFN frame: 21.4 lbs (9.7 kg)
Power
Inputs
Two independent AC inputs
Connector Type
IEC with cord retention
AC voltage
100 V to 240 V, 50/60 Hz
Maximum power dissipation
TX frame: 30 W
TF- and TFN frames: 100 W
Environmental
Operating temperature
0 to 45 degrees C
Non-operating temperature
-10 to +70 degrees C
Humidity
< 90% non-condensing
Table 9. 8900 Series Frame Specifications - (continued)
Parameter
Value