beautypg.com

Enabling alarms and fan speed control option, Frame monitor module indicator leds – Grass Valley 8900 Frames Gecko 2009 User Manual

Page 51

background image

Gecko Frames — Instruction Manual

51

Frame Monitor Module

Enabling Alarms and Fan Speed Control Option

The Frame Monitor module has an eight position DIP switch (S1) that
enables or disables the alarm functions and the variable fan speed function.

Refer to

Figure 20 on page 50

for the location of S1 and

Table 7

for the pos-

sible settings. A settings table is also silkscreened on the module.

Frame Monitor Module Indicator LEDs

The possible LED status and conditions indicated are shown in

Table 8

.

Table 7. Configuration DIP Switch Settings

Segment

Left Position (open)

Right Position (closed)

1

PS1 Fault Reporting Enabled

PS1 Fault Reporting Disabled

2

PS2 Fault Reporting Enabled

PS2 Fault Reporting Disabled

3

Overtemp Fault Reporting Enabled

Overtemp Fault Reporting Disabled

4

Fan Fault Reporting Enabled

Fan Fault Reporting Disabled

5

Module Fault Reporting Enabled

Module Fault Reporting Disabled

6

Fan Speed Controlled by Temperature

Fan Speed Fixed at Maximum

7

Not Used

8

Not Used

Table 8. Indicator LEDs and Conditions Indicated

LED

LED State

Condition

Power

(green)

Off

Power is off or onboard regulator has failed

On continuously

Module is powered

PS2

(red)

Off

Normal operation or alarm disabled

On continuously

Power supply 2 is present and reporting an alarm condition

PS1

(red)

Off

Normal operation or alarm disabled

On continuously

Power supply 1 is present and reporting an alarm condition

FAN

(red)

Off

Normal operation or alarm disabled

On continuously

One or more fans in the front cover assembly is not rotating

MOD
(red)

Off

Normal operation or alarm disabled

On continuously

Module health bus is not disabled and one or more modules is reporting an internal fault

Flashing

One or more modules is reporting a data error

INHIB

(yellow)

Off

Normal operation or alarm disabled

On continuously

A non-compliant module in the frame has disabled the module health bus

FAULT

(red)

Off Normal

operation

On continuously

One or more of the onboard fault LEDs is illuminated or flashing