beautypg.com

Frame alarm conditions – Grass Valley 8900 Frames Gecko 2009 User Manual

Page 42

background image

42

Gecko Frames — Instruction Manual

Section 2 — Installation

Frame Alarm Conditions

The conditions monitored by Frame Alarm reporting are:

Frame Health

Power supply 1 voltage

Power supply 2 voltage

Fan rotation

Frame temperature

Module Health Bus (8900 Video Frames only)

Power supply voltage

Signal present at input

EQ warning

The Module Health bus provides a means for older (legacy) or less capable
modules (such as DAs with no microprocessor) that cannot communicate
over the Frame serial bus to report alarm conditions to the Frame Monitor
or 8900NET module. The reporting is done using a voltage level sent by the
module to the Frame Alarm connector. When a problem exists on the
module, the Module Health bus will indicate that a problem exists on the
module but will not indicate what the problem is.

Alarm conditions are enabled or disabled by using the Alarm Reporting
DIP switch(es) on either the Frame Monitor or 8900NET modules. Refer to

Enabling Alarms and Fan Speed Control Option on page 51

for the Frame

Monitor module. For information on setting the 8900NET switches, refer to
the 8900 Network Interface Module Instruction Manual.

In addition to fault reporting through the Frame Alarm connector, there is
a red Fault LED on the 8900TF/TFN front cover. This LED is off when no
fault conditions are detected and on when either an internal fault or a signal
error is detected.

This manual is related to the following products: