beautypg.com

Specifications, Introduction, Frame specifications – Grass Valley 8900 Frames Gecko 2009 User Manual

Page 53: Section 5 — specifications

background image

Gecko Frames — Instruction Manual

53

Section

5

Specifications

Introduction

This section discusses specifications for the Gecko 8900 frames and the
8900PSX 100 W power supply. Refer to the module instruction manual for
the specifications for a particular audio/video module.

Frame Specifications

See

Table 9

for a list of the 8900 Series frame specifications. Specifications

are subject to change without prior notice.

Table 9. 8900 Series Frame Specifications

Parameter

Value

Module Cells

Input Type

75

Ω loop through BNCs (shield-isolated from ground)

Termination (Serial Digital)

CONARE BCP-TA (or equivalent,

customer-supplied)

Output Type

Eight 75

Ω BNCs

Frame Fault Reporting

Connector Type

DB-9F pins 8 and 9 of RS-232 connector

Maximum Current — Alarm OFF

100 µA when voltage < 24 V is applied

Maximum Voltage — Alarm ON

2 V with current < 20 mA

Maximum allowable voltage —
center conductor to shield

24 V

Maximum allowable current

20 mA

Front Panel Indicators

PS 1 & PS 2

Green LED — ON indicates operating correctly

Fault (TF/TFN front covers only)

Red LED — ON indicates an error or failure

This manual is related to the following products: