beautypg.com

Grass Valley ADVC-700 User Manual

Page 15

background image

Chapter 2 - Basic Operations

15

• MODE switch

Used to switch on the operation mode of the ADVC700. Pressing the switch will activate the
Encode operation and Decode operation alternatively.
When “ANALOG DV” LED illuminates, ADVC700 converts input analog signal to DV signal
(DV Encode). When “DV ANALOG” LED illuminates, it converts input DV signal to analog
signal (DV Decode).

•STATUS LED

Displays the following status.

Off: .................... 9-pin remote control is disabled.
Lit green: .......... 9-pin remote control is enabled.
Lit red: .............. 9-pin remote control has been set to enabled, but remote control is prevented

by a communication error. Check that the 9-pin remote cable is correctly
connected, that the connected device’s power is ON, and that the remote
control setting has been enabled on the connected device.

Flashing red: .... A major ADVC700 operation error has occurred, or several signals required

for operation can’t be detected. Check the error status display screen. Input
the required signals correctly, or change ADVC700’ settings.

* For more information on error status, see “Error status screen“ (p.22).