Onboard jumpers – Grass Valley 8964DEC v.1.1.0 User Manual
Page 28

28
8964DEC/-FS — Instruction Manual
Configuration
Onboard Jumpers
Two onboard jumpers (
) must be set for the following:
•
Jumper JP1 allows or locks out (Local) remote control.
•
Jumper JP3, OSD enables (OSD_EN pins 2-3) or disables (pins 1-2)
control of the OSD (On Screen Display).
The On Screen Display (OSD) graphic can be enabled on the output of
each channel to allow viewing of the currently selected Rotary switch
function and the currently assigned parameters. The OSD is provided
for an aid in configuring the module in local mode and should be
turned off on each channel with either the local or remote controls
before broadcasting the signal. When control is enabled with jumper
JP3, the OSD for each channel can be turned on or off with either local
or remote controls.
Figure 9. Module Configuration Switches and LEDs
8208_06
r1
Place jumper in Local position
to lock out remote access.
Function rotary switch
2ND Function LED
CM1 LED
CM0 LED
Pushbutton switch
Paddle switch
LOCAL
&REM (2–3)
CSM LED
Remote Lockout
LOCAL (1–2)
JP1
On Screen Display Control
JP3
(1–2)
(2-3)
OSD_EN