beautypg.com

Grass Valley 8949MDA-CXF User Manual

Page 30

background image

30

8949MDA-CXF/-SXF — Instruction Manual

Configuration

Web Page Operations and Functional Elements

The following conventions and functional elements (shown at left) are used
in GeckoFlex web page operations. (The examples shown throughout this
manual represent 8900NET software version 4.3.0):

Pulldown menus allow you to choose selections from a list.

Clicking on a button performs an immediate action such as recall of
defaults, clearing of states, learning configurations, and selecting all or
none of a selection.

Radio buttons are used to make a choice of one parameter in a group.

Check boxes are used when a selection can be enabled or included in a
group. Multiple check box selections or enables can be made for some
parameters.

A

Refresh

button (circular arrow) is provided at the top of each web page

for manual refresh to view recently changed parameters.

Each numerical adjustment control has a

Coarse

adjust button (left and

right top double arrows) which increases or decreases the step value by
a factor of 10. The

Fine

adjust button (left and right inside single arrows)

increases or decreases the step value by 1.

To change a value, use the arrow button controls or enter a value into
the number field and select the

Enter

button (

*

) or use the

Enter

key on

your keyboard. The Status Indicator bar will follow the value selected.

Use the

Low

and

High

Limit

buttons to go directly to the lowest and

highest limits for the parameter.

After a parameter has been changed, it will take approximately 10
seconds for the change to be entered into the module backup memory.
Allow the module enough time to update the change before removing
the module from its slot.

An entry field allows naming of various module functions such as
input or output signals, asset tag, and slot identification.

The

Status

LED icon indicates module status and is a link to the module

Status web page where status is reported.

LED colors indicate:

Green = Pass – no problems detected

Yellow = Configuration error warning

Red = Fault condition detected (presence of at least one alarm)

Pulldown Menus

Check box

Refresh button

Coarse Adjust

Fine Adjust

Enter

Status LED

Entry Field

High Limit

Status Indicator

Low Limit

Radio button

8341_13

Button

This manual is related to the following products: