8949MDA-CXF/-SXF — Instruction Manual

17

Installation

Fiber Optic Cleaning Requirement

Before making any fiber optic cable mating connections and after every
de-mating cycle, use an industry standard fiber optic cleaning kit,
including oil-free compressed air, to clean the fiber connectors and the con-
nectorized fiber end ferrules. This helps ensure optimum performance of
the fiber optic interface. Industry standard fiber optic cleaning kits can be
purchased on the web and in electronics stores.

Install Mounting Bracket on Submodule

Install the mounting bracket onto the submodule as illustrated below.

1.

Insert the narrow end (SCA-2 connector) of the submodule into the
mounting bracket, label side up with the open slots on the bracket
pointing to the rear as shown by the direction of the arrow in

Figure 6

.

Figure 6. Mounting Bracket

2.

Attach the mounting bracket to the submodule by sliding the bottom
part of the bracket under the V-connection (

Figure 7

) on the bottom side

of the submodule to hold it in place. Make sure the open bracket slots
point towards the SCA-2 (electrical) connector on the submodule.

Figure 7. Attach Bottom of Bracket to Submodule

3.

The finished installation should look like the example in

Figure 8

.

Figure 8. Finished Bracket Mounting

V-connection

SCA-2 (electrical) connector

Jumper cable connectors

SCA-2 (electrical) connector