Ould be on. refer to, To s – Grass Valley 8949MDA-CXF User Manual
Page 26
26
8949MDA-CXF/-SXF — Instruction Manual
Power Up
A red FAULT LED indicates an error situation and, when noted with the
other indicator LEDs, can indicate a specific problem area.
describes
signal output and LED indications for the various input/reference combi-
nations.
Table 4. LED Indicators
LED
Indication
Condition
FAULT
(red)
Off Normal
operation
On continuously
Module has detected internal fault
COMM
(yellow)
Off
No activity on frame communication bus
Long flash
Location Command received by the module from a remote control system
Short flash
Activity present on the frame communication bus
CONFIG
(yellow)
Off
Module is in normal operating mode
On continuously
Module is initializing, changing operating modes or updating firmware
PWR
(green)
Off
No power to module or module’s DC/DC converter failed
On continuously
Normal operation, module is powered
PRES OPT MOD
(yellow)
Off
Fiber optic submodule not installed
On
Fiber optic submodule installed
COMPOSITE SETUP
(green)
Off
Setup disabled
On
Setup enabled
FACTORY
(yellow)
Off
Normal operation
On
Test mode or factory mode
MONITORING MODE
(Channel 1
F0, F1, F2 and F3)
(yellow)
F0
F1
F2
F3
Off
Off
Off
Off
0000 --> Auto
Off
Off
Off
On
0001 --> 1080i/50
Off
Off
On
Off
0010 --> 1080i/59.94
Off
Off
On
On
0011 --> 720p/50
Off
On
Off
Off
0100 --> 720p/59.94
Off
On
Off
On
0101 --> 480i/59.94
Off
On
On
Off
0110 --> 576i/50
Channel 1
PRES SIG EQ
(green)
Off
No presence of signal on BNC J9 connector
On continuously
Presence of signal on BNC on J9 connector
PRES SIG OPT 1
(yellow)
Off
No presence of optical signal on Fiber optic input 1
On continuously
Presence of optical signal on Fiber Optic input 1
PRES SIG OPT 2
(yellow)
Off
No presence of optical signal on Fiber optic Input 2
On continuously