Power Up
Power Up
The onboard LED indicators are illustrated in
. Upon power-up,
the green PWR LED should light and the CONFIG, FAULT and COMM
LEDs should illuminate during the module initialization.
Note
When a module is first plugged into a GeckoFlex frame, the 8900NET module
(if present) may report a momentary fault. This will clear once the module has
booted up.
Operation Indicator LEDs
With a valid input signal connected, the Channel 1 PRES SIG LED EQ
(input to BNC J9), OPT 1, and/or OPT 2 (depends on presence and type of
fiber optic submodule) should be on. Refer to
to see a
complete list of possible operating conditions and the resulting indicator
status.
Note
Channel 2 Monitoring Mode LEDs are not present or used at this time.
Figure 14. Front Module Indicator LED