Table of alarms, Module repair – Grass Valley 8949MDA-CFR v.1.0.X User Manual
Page 30

30
8949MDA-CFR and 8949MDA-SFR Instruction Manual
Service
Table of Alarms
The table below describes the different type of alarms:
Module Repair
If the module is still not operating correctly, replace it with a known good spare and
return the faulty module to a designated Grass Valley repair depot. Call your Grass
Valley representative for depot location.
at the front of this document for the Grass Valley
Customer Service Information number.
Table 7. List of Alarms for 8949MDA module
Alarm
type
Web Page Description
LED concerned
Comments
Query status
towards
Netcard&SNMP
Fault
Firmware failure
if the firmware is wrong or after a bad download
STATUS PAGE:
The color of the front module becomes red
YES
Fault
Optical failure
YES
Fault
Optical submodule communication
error
communication problem with the optical module
YES
Fault
Software/Firmware version
incompatible
YES
Warning
Signal not Present on BNC Input
PRES COAX IN
(green)
STATUS PAGE:
The electrical input arrow is yellow
SETTING PAGE:
The carrier detect option is not present
YES
Warning
Wrong Rear Module
The rear module is not compatible with the front module
8949MDA-CFR or 8949MDA-SFR
YES
Warning
Signal not Present on Optic Input 1
PRES OPT IN 1
(orange)
STATUS PAGE:
Optic input arrow is yellow
YES
Warning
Signal not Present on Optic Input 2
PRES OPT IN 2
(orange)
STATUS PAGE:
Optic input arrow is yellow
YES
Warning
Mismatch or unknown format
Format detected different of format selected or unknown
format detected
NO
Warning
Module not locked
NO
Warning
Incoming bit stream error
Video input signal have a bit stream error
NO