Installation
To install the fiber optic submodule:
1.
Install the rear module, refer to Rear Module Installation
2.
Install the front module, refer to Front Module Installation
.
3.
Slide the fiber optic submodule into the cage connector (the label on the right).
Figure 5. Fiber Optic Submodule
4.
Before inserting the fiber cable, it is important to clean it with alcohol and a
lint-free filter paper.
The fiber optic submodule is hot-pluggable and may be installed or removed with
power applied to the front module.
The module type is identified by name on the label or can be identified by the direc-
tion of the two arrow indicators on the label.
Note
When installed properly, the front end of the submodule will line up with the
BNCs. Do not try to force it in further.
To extract the fiber optic submodule follow the steps:
Note
The fiber cable and the fiber optic submodule must be extracted before the
front and the rear modules.
1.
Remove the fiber cable first.
FIBER