Service – Grass Valley 8937 v.1.1.0 User Manual
Page 42

42
8937/8937D — Instruction Manual
Service
Service
The 8937 and 8937D modules make extensive use of surface-mount tech-
nology and programmed parts to achieve compact size and adherence to
demanding technical specifications. Circuit modules should not be ser-
viced in the field unless directed otherwise by Customer Service.
If your module is not operating correctly, proceed as follows:
•
Check frame and module power and signal present LEDs.
•
Verify power at the voltage testpoints (see
) and check fuse if
no voltage is detected.
•
Check for presence and quality of input signals.
•
Verify that source equipment is operating correctly.
•
Check cable connections.
for the location of the PWR LED and
for proper LED indications.
If the module is still not operating correctly, replace it with a known good
spare and return the faulty module to a designated Grass Valley repair
depot. Call your Grass Valley representative for depot location.
Refer to the Contacting Grass Valley
at the front of this document
for the Grass Valley Customer Service Information number.
Figure 21. 8937 and 8937D Fuse and Voltage Testpoint Locations
GRASS VALLEY 8937D SDI/ASI RECLOCKING EQ SNMP DA
8937
F1
2AMP
125V
FAST
8270_08
FAUL
T
COMM
CONF
PWR
SIG
PRES
BYP
ASS
143Mb
177Mb
260Mb
360Mb
REM
OVR
J8
Voltage
Test Points
2
+5V
GND
Fuse