beautypg.com

Grass Valley 8937 v.1.1.0 User Manual

Page 32

background image

32

8937/8937D — Instruction Manual

Configuration

8937D Module

The Standard Selections page for the 8937D (

Figure 18 on page 33

) provides

separate controls for DA 1 and DA 2 signal loss reporting and standard
selection.

Note

Each DA has a separate Report Loss of Signal control. On the Status web
page, input signal status reporting is collective as described in

Status Web

Page on page 28

. SNMP reporting is separate as described in

SNMP Trap

Reports on page 37

.

Click the

Apply

button to enter all values.

For DA 1:

Set Report Loss of Sig 1 as

Yes

or

No

. See Note above.

Set the Mode 1 control for DA 1 to

Auto

(input bit rate standard detected

by module),

Manual

(input bit rate standard selected manually), or

Bypass

(input bypasses reclocking circuitry).

The Input Signal 1 field will report the status of the DA 1 input signal.

When

Auto

mode is selected, the bit rate currently detected by the

module will be displayed in the Current Bit Rate 1 field as shown in the
example in

Figure 18 on page 33

.

When

Bypass

mode is selected,

Bypass

will be displayed in the Current

Bit Rate 1 field.

When

Manual

mode is selected, a Standard Selection 1 pulldown will

appear similar to the one shown previously in the 8937 DA 1 illustra-
tion in

Figure 17 on page 31

. Select the bit rate from the Standard Selec-

tion 1 pulldown (

143 Mb

,

177 Mb

,

270 Mb

, or

360 Mb

) as desired. The

currently selected manual rate will be shown next to the pulldown.

For DA 2:

Set Report Loss of Sig 2 as

Yes

or

No

. See Note above.

Set the Mode 2 control for DA 2 to

Auto

(input bit rate standard detected

by module),

Manual

(input bit rate standard selected manually), or

Bypass

(input bypasses reclocking circuitry).

The Input Signal 2 field will report the status of the DA 2 input signal.

When

Auto

mode is selected, the bit rate currently detected by the

module will be displayed in the Current Bit Rate 2 field.

When

Bypass

mode is selected,

Bypass

will be displayed in the Current

Bit Rate 1 field as shown in the example in DA 2 in

Figure 18 on page 33

.

When

Manual

mode is selected, a Standard Selection 2 pulldown will

appear. Select the bit rate from the Standard Selection 2 pulldown
(

143 Mb

,

177 Mb

,

270 Mb

, or

360 Mb

) as desired. The currently selected

manual rate will be shown next to the pulldown.

This manual is related to the following products: