8937/8937D — Instruction Manual

Configuration

Local On-Board Configuration

8937 Module

Two on-board jumpers are present on the 8937 module to configure module
formatting if not using the remote controls. Refer to

Figure 9

for jumper

locations on the module circuit board.

DA 1 – set jumper J6 for AUTO (pins 1-2) to enable auto reclocking (for
signal data rates of 143, 177, 270, and 360 Mb/s), 270 Mb only (jumper
pin 2 only), or BYPASS (pins 2-3) to bypass reclocking (for signals with
data rates of 50 Mb/s to 360 Mb/s). This setting can be overridden by
remote controls.

Local/Remote – set jumper J7 to LOCAL (pins 1-2) to lock out remote
control or LOCAL & REMOTE (pins 2-3) for access to remote control.
This setting cannot be overridden by remote controls.

Figure 9. 8937 On-Board Jumper Locations

GRASS VALLEY 8937D SDI/ASI RECLOCKING EQ SNMP DA

8937

8270_06

r2

FAUL
T

COMM

CONF

PWR

SIG

PRES

BYP

ASS

143Mb

177Mb

260Mb

360Mb

REM

OVR

J7

J6

DA 1

AUTO (1-2)

270 Mb (pin 2)

BYPASS (2-3)

LOCAL/REMOTE

LOCAL &
REMOTE (2-3)

LOCAL (1-2)

Pins 2-3

Pins 1-2

Pin 2 only

Jumper Positions for J6