Slot config web page – Grass Valley 8937 v.1.1.0 User Manual
Page 35

8937/8937D — Instruction Manual
35
Configuration
Slot Config Web Page
Use
this
link
Use the Slot Config web page (
) to perform the fol-
lowing functions on the module:
Locate Module
Selecting the
Flash
button flashes the yellow COMM and CONFIG LEDs in
unison on the front of the module so it can be located in the frame.
Slot Identification
You may identify the module by typing a specific name in the
Name
field.
The assigned name is stored on the 8900NET module and travels with the
8900NET module if it is moved to another frame. Select
Default
to enter the
factory default module name.
An asset identification may be entered in the
Asset Tag
field up to 31 charac-
ters. This will appear on the module Status web page and in the NetConfig
PC application inventory report.
Slot Memory
When the
Restore upon Install
checkbox on any media module Slot Config
web page has been selected, the current configuration from that module is
saved in slot memory on the 8900NET module. This allows the current
module to be removed and when another module of the same part number,
and software version is installed, the configuration saved to the 8900NET
module will be downloaded to the installed module. The
Restore upon Install
checkbox must be selected before the current module with the saved con-
figuration is removed.
Note
Make sure all modules of the same model type are running the same software
version and have the same part number silk-screened on the printed circuit
board. Downloading a configuration to a module with a different software
version or part number can produce unexpected results.
If a different type of module is installed in this slot, a warning message will
state that the original module type has been replaced with another module
type. In this case, a
Clear
button will appear allowing you to clear the stored
configuration from the previous module.
You may also select the
Learn Module Config
button at any time to save the
current configuration for this slot. The configuration is saved on the
8900NET module. If the 8900NET module is removed or powered down,
the stored configurations are not saved.
Note