23

Configuration

8937D Module

Three onboard jumpers are present on the 8937D to configure module for-
matting. Refer to

Figure 10

for jumper locations on the circuit board.

DA 2 BYPASS/270 Mb/AUTO – for DA 2, set jumper J5 for AUTO
(pins 1-2) to enable auto reclocking (for signal data rates of 143, 177,
270, and 360 Mb/s), 270 Mb only (jumper pin 2 only), or BYPASS
(pins 2-3) to bypass reclocking (for signals with data rates of 50 Mb/s
to 360 Mb/s). This jumper setting can be overridden by remote controls.

DA 1 BYPASS/270 Mb/AUTO – for DA 1, set jumper J6 for AUTO
(pins 1-2) to enable auto reclocking (for signal data rates of 143, 177,
270, and 360 Mb/s), 270 Mb only (jumper pin 2 only), or BYPASS
(pins 2-3) to bypass reclocking (for signals with data rates of 50 Mb/s
to 360 Mb/s). This jumper setting can be overridden by remote controls.

Local/Remote – set jumper J7 to LOCAL (pins 1-2) to lock out remote
control or LOCAL & REMOTE (pins 2-3) for access to remote control.
This jumper setting cannot be overridden by remote controls.

Figure 10. 8937D On-Board Jumper Locations

GRASS VALLEY 8937D SDI/ASI RECLOCKING EQ SNMP DA

8937

FAUL
T

COMM

CONF

PWR

SIG

PRES

DA 1

DA 2

BYP

ASS

143Mb

177Mb

270Mb

360Mb

REM

OVR

SIG

PRES

BYP

ASS

143Mb

177Mb

270Mb

360Mb

8270_06

r2

J5

J7

J6

DA 1

AUTO (1-2)

270 Mb (pin 2)

BYPASS (2-3)

LOCAL/REMOTE

LOCAL &
REMOTE (2-3)

LOCAL (1-2)

DA 2

AUTO (1-2)

270 Mb (pin 2)

BYPASS (2-3)

Pins 1-2

Pins 2 only

Pins 2-3

Jumper Positions for J5/J6