8937d module – Grass Valley 8937 v.1.1.0 User Manual
Page 23

8937/8937D — Instruction Manual
23
Configuration
8937D Module
Three onboard jumpers are present on the 8937D to configure module for-
matting. Refer to
for jumper locations on the circuit board.
•
DA 2 BYPASS/270 Mb/AUTO – for DA 2, set jumper J5 for AUTO
(pins 1-2) to enable auto reclocking (for signal data rates of 143, 177,
270, and 360 Mb/s), 270 Mb only (jumper pin 2 only), or BYPASS
(pins 2-3) to bypass reclocking (for signals with data rates of 50 Mb/s
to 360 Mb/s). This jumper setting can be overridden by remote controls.
•
DA 1 BYPASS/270 Mb/AUTO – for DA 1, set jumper J6 for AUTO
(pins 1-2) to enable auto reclocking (for signal data rates of 143, 177,
270, and 360 Mb/s), 270 Mb only (jumper pin 2 only), or BYPASS
(pins 2-3) to bypass reclocking (for signals with data rates of 50 Mb/s
to 360 Mb/s). This jumper setting can be overridden by remote controls.
•
Local/Remote – set jumper J7 to LOCAL (pins 1-2) to lock out remote
control or LOCAL & REMOTE (pins 2-3) for access to remote control.
This jumper setting cannot be overridden by remote controls.
Figure 10. 8937D On-Board Jumper Locations
GRASS VALLEY 8937D SDI/ASI RECLOCKING EQ SNMP DA
8937
FAUL
T
COMM
CONF
PWR
SIG
PRES
DA 1
DA 2
BYP
ASS
143Mb
177Mb
270Mb
360Mb
REM
OVR
SIG
PRES
BYP
ASS
143Mb
177Mb
270Mb
360Mb
8270_06
r2
J5
J7
J6
DA 1
AUTO (1-2)
270 Mb (pin 2)
BYPASS (2-3)
LOCAL/REMOTE
LOCAL &
REMOTE (2-3)
LOCAL (1-2)
DA 2
AUTO (1-2)
270 Mb (pin 2)
BYPASS (2-3)
Pins 1-2
Pins 2 only
Pins 2-3
Jumper Positions for J5/J6