Track configuration task list, Associating track with nqa – H3C Technologies H3C WX3000E Series Wireless Switches User Manual
Page 46

38
Track configuration task list
To implement the collaboration function, establish associations between the track module and the
detection modules, and between the track module and the application modules.
Complete these tasks to configure the track module:
Task Remarks
Associating the track module
with a detection module
Required.
Use any of the
approaches.
Associating track with interface management
Associating the track module
with an application module
Required.
Use any of the
approaches.
Associating track with static routing
Associating track with WLAN uplink detection
Associating the track module with a detection
module
Associating track with NQA
NQA supports multiple test types to analyze network performance, services, service quality. For example,
an NQA test group can periodically detect whether a destination is reachable, or whether the TCP
connection to a TCP server can be set up. After being associated with a track entry, an NQA test group
tells the track module that the tracked object malfunctions when the consecutive failures reach the
specified threshold. Then the track module sets the track entry to the Negative state. If the specified
threshold is not reached, the NQA module tells the track module that the tracked object functions
properly. The track module then sets the track entry to the Positive state. For more information about NQA,
see Network Management and Monitoring Configuration Guide.
To associate track with NQA:
Step Command
Remarks
1.
Enter system view.
system-view
N/A
2.
Create a track entry,
associate it with an NQA
reaction entry, and specify the
delay time for the track
module to notify the
associated application
module when the track entry
status changes.
track track-entry-number nqa entry
admin-name operation-tag reaction
item-number [ delay { negative
negative-time | positive
positive-time } * ]
No track entry exists by default.
NOTE:
If the specified NQA test group or the reaction entry in the track entry does not exist, the status of the track
entry is Invalid.
- H3C WX5500E Series Access Controllers H3C WX3500E Series Access Controllers H3C WX2500E Series Access Controllers H3C WX6000 Series Access Controllers H3C WX5000 Series Access Controllers H3C LSWM1WCM10 Access Controller Module H3C LSUM3WCMD0 Access Controller Module H3C LSUM1WCME0 Access Controller Module H3C LSWM1WCM20 Access Controller Module H3C LSQM1WCMB0 Access Controller Module H3C LSRM1WCM2A1 Access Controller Module H3C LSBM1WCM2A0 Access Controller Module