beautypg.com

Fan failure, Configuration terminal problems, No terminal display – H3C Technologies H3C S5120 Series Switches User Manual

Page 41: Garbled terminal display

background image

33

Fan failure

You can look at the system status LED and the seven-segment LED of an S5120-EI switch to identify a fan
failure. If both LEDs are behaving as described in

Table 6

, a fan failure occurs.

Table 6 Fan failure LEDs description

LED Mark

State

System status LED

PWR/SYS

Steady red

Seven-segment LED

Unit

The LED flashes F for fan failure.

The S5120-EI Switch Series uses built-in fans. If a built-in fan failure occurs, contact your H3C sales agent

or service engineer for assistance and do not attempt to fix the problem yourself.

NOTE:

To ensure normal operation of the switch, contact the local sales agent or service engineer as soon as
possible when a built-in fan failure occurs.

Configuration terminal problems

If the configuration environment setup is correct, the configuration terminal displays booting information

when the switch is powered on. If the setup is incorrect, the configuration terminal would display nothing

or garbled text.

No terminal display

If the configuration terminal displays nothing when the switch is powered on, verify that:

The power supply is normal.

The console cable is correctly connected.

The console cable has no problem and the terminal settings are correct.

Garbled terminal display

If terminal display is garbled, verify that the following settings are configured for the terminal, for

example, HyperTerminal:

Baud rate—9,600

Data bits—8

Parity—none

Stop bits—1

Flow control—none

Emulation—VT100

This manual is related to the following products: