Maintenance and troubleshooting, Software loading failure, Power supply failure – H3C Technologies H3C S5120 Series Switches User Manual

Page 39: Ac input

background image

31

Maintenance and troubleshooting

Software loading failure

The switch runs with the original software version after it has failed to load new version of software. To

identify and remove the loading failure cause, perform the following check procedure:

Verify that the physical ports are correctly connected.

If the physical connection is loose or incorrect, reconnect the physical ports and make another try

to load software.

If the physical connection is secure and correct, view the loading procedure information displayed
on the HyperTerminal to check for input errors, and make another try to load software.

For example, when using XMODEM, verify that you have reset the baud rate of the HyperTerminal to

9,600 bps after loading the software with a baud rate other than 9,600 bps; when using TFTP, verify that

you have specified the correct server and switch IP addresses, the correct name of the software to be
loaded and the correct working path of TFTP server; when using FTP, verify that you have specified the

correct server and switch IP addresses, the correct name of the software to be loaded and the correct

username and password.
If software loading fails for any other cause than physical connection problems and input errors, please

contact your sales agent for assistance.

Power supply failure

The S5120-EI Switch Series uses built-in power modules. Each of the S5120-EI Switch Series has three

input modes, namely, AC input, RPS input and both.
You can look at the system status LED and the RPS status LED on the front panel of the switch to identify

a power system failure. For relevant information, see

Table 5

.

Table 5 Built-in power module failure LEDs description for the S5120-EI Switch Series except the

S5120-20TP-EI

LED Mark Status

Description

System status LED

PWR

Off

The switch is powered off.

RPS status LED
(S5120-28C-EI,

S5120-52C-EI,
S5120-24P-EI, and

S5120-48P-EI)

RPS

Steady yellow

The RPS input is normal, but the AC input fails or
is not connected.

Off

RPS is not connected.

RPS status LED
(S5120-28C-PWR-EI

and
S5120-52C-PWR-EI)

RPS

Steady yellow

The RPS input is normal, but the AC input fails or
is not connected.

Off

The RPS input is abnormal.

AC input

If the system status LED is off, an AC input failure has occurred. Check the following items: