38
Item S5130-28S-EI
S5130-28TP-EI S5130-52S-EI S5130-28F-EI S5130-52TP-EI
10/100/100
0Base-T
autosensing
Ethernet ports
24
24
48
8 (Each and its
corresponding
SFP port form a
combo
interface.)
48
1/10GBase-T
autosensing
Ethernet ports
N/A 2
N/A N/A 2
100/1000Ba
se-X SFP ports
N/A N/A N/A
24 (The
rightmost eight
SFP ports and
their
corresponding
10/100/1000
Base-T
autosensing
Ethernet ports
form combo
interfaces.)
N/A
SFP+ ports
4
2
4
4
2
Power module
slots
N/A N/A N/A
2, on the rear
panel
N/A
Input voltage
•
Rated voltage: 100 VAC to 240
VAC @ 50 or 60 Hz
•
Max voltage: 90 VAC to 264
VAC @ 47 to 63 Hz
•
AC power source
{
Rated voltage: 100 VAC to 240 VAC @ 50 or 60
Hz
{
Max voltage: 90 VAC to 264 VAC @ 47 to 63
Hz
•
DC power source: –48 V DC power source in the
equipment room or RPS (recommended H3C
models: RPS800-A or RPS1600-A)
{
Rated voltage: –48 VDC to –60 VDC
•
Max voltage: –36 VDC to –72 VDC
Minimum
power
consumption
19 W
20 W
•
AC: 38 W
•
DC: 38 W
•
AC: 30 W
•
DC: 38 W
•
AC: 36 W
•
DC: 36 W
Maximum
power
consumption
26 W
34 W
•
AC: 45 W
•
DC: 50 W
•
AC: 60 W
•
DC: 68 W
•
AC: 54 W
•
DC: 54 W
Chassis
leakage
current
compliance
•
UL60950-1
•
EN60950-1
•
IEC60950-1
•
GB4943.1
Melting
current of
power module
fuse
2 A/250 V
2 A/250 V
•
AC-input:
10 A/250
V
•
DC-input: 5
A/250 V
•
AC-input: 5
A/250 V
•
DC-input: 8
A/250 V
•
AC-input: 10
A/250 V
•
DC-input: 5
A/250 V