beautypg.com

Ip adr menu – Ensemble Designs 9455 3G Clean and Quiet Protection Switch User Manual

Page 46

background image

www.ensembledesigns.com

7435 and 9455 - page 46

Model 7435 and 9455 Clean and Quiet Protection Switches

Detailed Instructions for Updating Software in your 9455 or 7435:

Updating Software: Step 1. Connecting the Cable

Attach the 23700048 Interface Adapter Cable to the 15 pin D connector associated with the clean

switch module on the back of the Avenue frame. Connect an Ethernet cable from the Ethernet port

end of the “Y” cable to your network. The Ethernet port will auto-sense cable direction, so a cross-over

cable is not needed.

Updating Software: Step 2. Setting the IP Address

Assign a unique IP address to the 9455/7435 module. Use the IP Address menu in Avenue PC or on

your Touch Screen. The IP Address menu is detailed below an illustrated on the following page.

IP Adr Menu

The IP Adr menu shown on the following page allows you to change the IP address of your

94555/7435 module. When you initially power up the 9455 or 7435 as received from the factory, it will

take the self-assigned static IP address of 192.168.1.100. In order to use the Ethernet port to update

module software, you will need to assign anew IP address.

These are general instructions. We recommend that you consult your IT staff if you are uncertain about

any of these network configuration settings.

To Set the IP Address

1. From the IP Adr menu, enter the IP address you want to use that is compatible with your own

network. The simplest method is to touch each number field, using the keypad to enter the new

numbers. For example, you may want to change the IP address to something like the following:

10.123.222.100. These are general instructions. We recommend that you consult your IT staff if you

are uncertain about any of the network configuration settings.

2. Press Save. Both the Cancel and Save buttons turn black to indicate that your new settings have

been saved.

Note that when using Avenue PC instead of the Touch Screen interface, after entering numbers into

the number fields, you will need to hit the “enter” or “return” key for the change to register.