beautypg.com

Getting started, Output menu – Ensemble Designs 9455 3G Clean and Quiet Protection Switch User Manual

Page 17

background image

www.ensembledesigns.com

7435 and 9455 - page 17

Model 7435 and 9455 Clean and Quiet Protection Switches

Getting Started

Output Menu

The first step setting up your clean protection switch is to assign the output standard to the module

in the Output menu. The Output menu screen shown on the following page allows you to select your

output standard, and to enable or disable embedded audio in all four audio Groups.

• Output Std – select the output standard from the following:

720p/50

720p/59.94

720p/60

1080i/50

1080i/59.94

1080i/60

1080p/25

1080p/23.98

1080p/24

3G 1080p/50

3G 1080p/59.94

3G 1080p/60

1080sF/25

1080sF/23.98

1080sF/24

SD525

SD625

The default setting is 1080i/59.94

Note that the output standard selected in this menu must match the input standard of both

the Primary and Secondary inputs. If they output standard does not match the inputs, the

module will output timed black. This will be indicated in the Switch Position reporting

window of the Status Menu. Additionally, on the front panel of the module the Primary Active

and Secondary Active LEDs will blink simultaneously.

• Embed Grp 1, Embed Grp 2, Embed Grp 3, Embed Grp 4 – the default setting and standard

operation for Embed Groups 1 through 4 is enabled. Disable only if you want to strip audio

from the output. When disabled an audio fault will trigger and be indicated in the status menu.