Getting started, Output menu – Ensemble Designs 9455 3G Clean and Quiet Protection Switch User Manual
Page 17
www.ensembledesigns.com
7435 and 9455 - page 17
Model 7435 and 9455 Clean and Quiet Protection Switches
Getting Started
Output Menu
The first step setting up your clean protection switch is to assign the output standard to the module
in the Output menu. The Output menu screen shown on the following page allows you to select your
output standard, and to enable or disable embedded audio in all four audio Groups.
• Output Std – select the output standard from the following:
720p/50
720p/59.94
720p/60
1080i/50
1080i/59.94
1080i/60
1080p/25
1080p/23.98
1080p/24
3G 1080p/50
3G 1080p/59.94
3G 1080p/60
1080sF/25
1080sF/23.98
1080sF/24
SD525
SD625
The default setting is 1080i/59.94
Note that the output standard selected in this menu must match the input standard of both
the Primary and Secondary inputs. If they output standard does not match the inputs, the
module will output timed black. This will be indicated in the Switch Position reporting
window of the Status Menu. Additionally, on the front panel of the module the Primary Active
and Secondary Active LEDs will blink simultaneously.
• Embed Grp 1, Embed Grp 2, Embed Grp 3, Embed Grp 4 – the default setting and standard
operation for Embed Groups 1 through 4 is enabled. Disable only if you want to strip audio
from the output. When disabled an audio fault will trigger and be indicated in the status menu.