Config Menu
The Config menu shown on the following page allows you to configure the TRS Test, and enable or
disable the Audio Detect, Black Detect, Freeze Detect and Secondary Test Enable controls. When the
Audio Detect, Black Detect and/or Freeze Detect are enabled, use their specific menus to set detailed
parameters for each.
• TRS Test – enables the test for any Timing Reference Signal (TRS) errors.
Off – sets the input for no TRS test.
Lenient – allows occasional TRS errors to be ignored (10 frames in a row).
Strict – detects any TRS error as a fault.
Default setting is Lenient.
• Audio Detect – enables the test for embedded audio. Use the Aud Detect menu to set the
specific parameters for embedded audio detection.
On – detects an audio condition as determined by the settings made in the Aud Detect
menu.
Off – sets the input for no audio test.
Default setting is Off.
• Black Detect – enables the test for black detection. Use the Blk Detect menu the to set the
specific parameters for black detection.
On – detects black present as defined by the settings made in the Blk Detect menu.
Off – sets the input for no black test.
Default setting is On.
• Freeze Test – enables the test for a freeze condition. Use the Freeze menu the to set the
specific parameters for freeze detection.
On – detects an audio condition as determined by the settings made in the Freeze menu.
Off – Set to Off for no freeze test.
Default setting is On.
• Sec Test Enable – enables the test for checking the status of the Secondary input.
On – the Secondary status will be checked for the same configuration tests as assigned for
the Primary. On is the recommended setting.
Off – no vetting will be performed on the Secondary input.