Troubleshooting, Software updates – Ensemble Designs 7160 Serial Digital Protection DA User Manual
Page 41
![background image](https://www.manualsdir.com/files/812575/content/doc041.png)
www.ensembledesigns.com
7160-41
Model 7160 HD/SD/ASI/310 Protection DA
TROUBLESHOOTING
As a troubleshooting aid, reference signal status and presence, as well as power and CPU status can be
easily monitored from the front panel of the 7160 module using the front panel indicators.
Refer to the troubleshooting tips below:
Can’t control module
Check status of CPU Run green LED. Should be blinking slowly and in unison with other
•
modules if System module is present. If not, try removing it and plugging it in again to be sure
it is seated properly.
System module may not be working properly if installed.
•
Module remote controls are grayed out
Module is locked or access to module controls is restricted by User Level.
•
No signal out of module
Check status of Active LEDs. Primary or Secondary should be lit. If not, check the inputs for
•
signal presence and quality.
Check cabling to input of the module.
•
Please also refer to the technical support section of the Ensemble Designs web site for the latest
information on your equipment at the URL below:
http://www.ensembledesigns.com/support
SOFTWARE UPDATES
Software updates for each module can be downloaded remotely if the optional System Control
module is installed. These can be downloaded onto your PC, then Avenue PC will distribute the update
to the individual module. (Refer to the Avenue PC documentation for more information) Updates are
periodically posted on the Ensemble Designs web site. If you do not have the required System Control
Module and Avenue PC, modules can be sent back to the factory for software upgrades.