Config menu – Ensemble Designs 7160 Serial Digital Protection DA User Manual
Page 31

www.ensembledesigns.com
7160-31
Model 7160 HD/SD/ASI/310 Protection DA
Config Menu
The Config menu shown below allows you to configure the various condition detectors:
TRS Test
•
– enables the test for any Timing Reference Signal (TRS) errors. Off sets the input for
no TRS test, Lenient allows occasional TRS errors to be ignored (10 frames in a row), or Strict
detects any TRS error as a fault.
ASI Test
•
– enables the test for ASI or SMPTE 310M signals. On detects ASI or SMPTE 310M
present as determined by the settings made in the ASI Config menu, or Off sets the input for
no ASI or SMPTE 310M test.
Audio Detect
•
– enables the test for embedded audio. On detects an audio condition as
determined by the settings made in the Aud Detect menu, or Off sets the input for no audio
test.
Black Detect
•
– enables the test for black detection. On detects black present as defined by the
settings made in the Blk Detect menu, or Off sets the input for no black test.
Freeze Test
•
– On enables the test for a freeze condition as determined by the settings chosen
in the Freeze menu. Set to Off for no freeze test.