7160-16

Model 7160 HD/SD/ASI/310 Protection DA

7160

Serial

Protect

DA

In OK

Active

Auto

Remote
Local

Run

Pwr

Pri

Sec

Black

Freeze

Auto Reset

On/Off

Control

EDH/CRC

Audio

TRS

CC

Active

Front Panel Controls and Indicators

Each front edge indicator and switch setting of the 7160 is shown in the diagram below:

Pri In OK green LED:

ON when Primary input passes

all enabled tests.

OFF when Primary input fails an

enabled test.

Pri Active green LED:

ON when Primary input is

feeding the output.

OFF when Primary input is not

feeding the output.

Control Switch:

Momentary switch to set output

to Primary (Up) or Secondary

(Down).

Remote/Local switch:

Set to the mode you will use.

Run green LED:

OFF A power fault or halted CPU

ON A halted CPU

FAST BLINK CPU Run error

SLOW BLINK System OK. (If SPI

control is active from the main

frame System Control Module, all

Run indicators will be

synchronized.).

Pwr green LED:

Indicates the presence (ON) or

absence (OFF) of power (+5V).

Auto green LED:

ON when Auto is active.

OFF when Auto is turned off.

Sec Active red LED:

ON when Secondary input is

feeding the output.

OFF when Secondary input is

not feeding the output.

EDH/CRC switch:

Select On (left) to monitor for

EDH error condition as fault or

Off (right) for no EDH testing.

Audio switch:

Select On (left) to detect audio

silence condition as fault or Off

(right) for no audio detection.

Black switch:

Select On (left) to detect black

condition as fault or Off (right)

for no black detection.

Freeze switch:

Select On (left) to detect freeze

condition as fault or Off (right)

for no freeze detection.

Auto Reset switch:

Select On (left) to enable mod-

ule to auto reset when Primary

input is restored or Off (right) for

manual reset when Primary input

is restored.

TRS switch:

Select On (left) to monitor for

TRS error condition as fault or

Off (right) for no TRS testing.

CC switch:

Select On (left) to enable

detection of closed caption data

or Off (right) for no closed

caption detection. (Note: not yet

implemented.)