11 technical data, Technical data – ARAG Digiwolf Tank filling system User Manual
Page 22
22
11
teCHniCal data
Data
Min.
Max. Default UoM Notes
Calibration
Manual calibration
1
50,000
600
--
--
flowrate alarms
Min. flowrate alarm
0.1
99999.9
OFF
l/min.
The alarm can be deactivated
setting the value "OFF"
Max. flowrate alarm
0.1
999999.9
OFF
l/min.
The alarm can be deactivated
setting the value "OFF"
display
Brightness
0%
100%
50%
%
--
Contrast
0%
100%
50%
%
--
filling
Valve activation time
0.0
9.9
0.0
sec.
Filling quantity
0.1
99999.9
3000.0
litres
Options
Language
-
-
English
-
Language settings: Italiano,
English, Español,
Português, Français, Deutsch,
Cesky, Polski,
ニホン
, Русский, Magyar.
Rate units of
measurement
-
-
l/min.
-
Units of measurement set-
tings: l/min, GPM, m
3
/h
Volume units of
measurement
-
-
litres
-
Units of measurement set-
tings: l, gal, m
3
Description
Tank filling system
Power supply
12 Vdc ± 10%
Short circuit protection
•
Flowrate signal
square wave (0 ÷ V suppl.)
Max. frequency
1,2 KHz
Max. absorption
3 A
Working temperature
0 °C ÷ 60 °C
+32 °F ÷ +140 °F
Storage temperature
-30 °C ÷ 80 °C / -22 °F ÷ +176 °F
Dimensions
330x200x346 mm
Weight
3500 g
Tab 2
TECHNICAL DATA