ARAG Digiwolf Tank filling system User Manual
Page 19
19
10 MaintenanCe
10.1
Notes on maintenance
- At the end of each treatment, run clean water through the tubes.
- Clean the tank filling system pipe with a special detergent on a regular basis.
- Clean (and if necessary, replace) the flowmeter paddle on a regular basis (page 19, chap 10.2)
- Do not use metal or abrasive objects to clean the paddle.
- Do not use solvents or fuel to clean the case outer surface.
10.2
Paddle cleaning and replacement
sblocca
blocca
4
4
2
7
1) Remove the fork from the monitor using a screwdriver.
2) Remove the monitor from the flowmeter body.
3) Unscrew the ring nut in a counter clockwise direction and remove the sensor housing block from
the flowmeter body.
4) With half a rotation, remove the paddle group from the sensor housing block in a counter clockwise
direction.
5) Immerse the paddle group in detergent liquid for several hours.
6) Wash the paddle group thoroughly with running water and check its correct operation. If necessary,
replace the complete paddle group with its suitable spare part
(code 4626000.500).
7) Refit the paddle group on the electronic sensor with a clockwise rotation until it clicks in place.
MAINTENANCE