10.4

Troubleshooting

fault

CauSe

ReMedy

The valve leaks or the seal of the
ball is not enough

Presence of foreign bodies

• Make sure there are no foreign bodies;
if so, remove them.

Worn seals

• Contact your nearest assistance centre.

The valve is not working and the
display is off

Lack of power

• Check the connections, the cables, and
the controls. Replace the cable.
If the problem persists, contact your
nearest service centre.

The valve does not work

Geared motor broken

• Replace the geared motor. The
instructions can be found on our Website
www.aragnet.com - ADDIN D30025.

The valve does not stop at the
preset point

Malfunction of the microswitches
in the geared motor

• Contact your nearest assistance centre.

Totalizers do not progress during the
passage of liquid.

Rate is beyond operation limits of
the flowmeter

• The model of the flowmeter is not ad-
equate for the flowrate to be measured.
Replace the flowmeter.

The paddle-wheel is locked

• Clean or replace the paddle-wheel group
if necessary.

Displayed flowrate is not stable

Presence of turbulence or air in
the circuit

• Check the circuit

.

Worn paddle

• Replace the paddle

.