Section
Setting Parameter Available Options
Option Description
Code 39
(cont’d)
Trioptic 39
Enabled/Disabled
Enable/Disable decoding of Tri-optic
brand symbols (used in magnetic tape
identification)
Conversion
1.) Disabled
No Code 39 to Code 32 conversion
2.) To Code 32
Convert data into Code 32 (Italian
Pharmacode) format
Code 32 Prefix
Enabled/Disabled
Add the Code 32 Prefix (A) when
converting from Code 39 to Code 32
Check Digit
1.) Ignore
Ignore Code 39 Check digit
2.) Verify
Verify Code 39 Check digit
3.) Transmit
Verify and Transmit Code 39 Check digit
Code 39 ASCII
Enabled/Disabled
Enable Full ASCII support in Code 39
Code 93
Code 93
Enabled/Disabled
Enable/Disable decoding of Code 93 symbols
Data Length 1
Min: 0 characters
** See Laser Data Lengths Note
Max: 50 characters
Data Length 2
Min: 0 characters
Max: 50 characters
Code 11
Code 11
Enabled/Disabled
Enable/Disable decoding of Code 11
symbols
Data Length 1
Min: 0 characters
** See Laser Data Lengths Note
Max: 80 characters
Data Length 2
Min: 0 characters
Max: 80 characters
Check Digits
1.) Ignore
Ignore Code 11 check digits
2.) One
Verify first Code 11 check digit
3.) Two
Verify both Code 11 check digits
Tx Check Digit
Enabled/Disabled
Enable/Disable the transmission of the
verified check digit(s)
2 of 5
Int 2of5
Enabled/Disabled
Enable/Disable decoding of Interleaved
2 of 5 symbols
Check Digits
1.) Ignore
Ignore Interleaved 2 of 5 check digit
2.) USS
Use Uniform Symbology Specification algorithm
3.) OPCC
Use Optical Product Code Council algorithm
Tx Check Digit
Enabled/Disabled
Enable/Disable the transmission of the
verified check digit