Parameter element, Indicators message, Indicators element – Wavecom W-RCI (Remote Control) V8.7.0 User Manual
Page 34
26
Information messages
XML SDK V8.7.0 Remote Control Interface
Parameter element
Attribute List
name
Name of the parameter. This attribute is required and is a string.
value
Value of the parameter. This attribute is required and is an integer, a floating point or a string value de-
pending on the parameter.
Content
This element has no content.
Note: A detailed description of the name and value pairs is found later in this document. The pairs can be
received with the MetaData message.
Indicators message
Attribute List
status
Status of the decoder. This attribute is required and is a choice between “idle”, “traffic”, “error”, “request”,
“auto”, “synchronise” and “phasing”.
level
Level indicator for the measured input gain. This attribute is required and represents an integer value
between 0 and 12.
bargraph
Value of a bargraph element. This attribute is required and represents a string of the form
XXXXXXXXXXXXXXXX. Each of the 16 X is the hexadecimal presentation of a 4 bit single bargraph bin val-
ue.
Content
This element has no content.