Issues, Xml messages, Scope – Wavecom W-RCI (Remote Control) V8.7.0 User Manual

Page 11: Constraints, Message categories

background image

XML SDK V8.7.0 Remote Control Interface

XML Messages

3

name”.
Small correction in “alphabet” parameter.

8.6.0

20-Oct-2014

Add the message “Confidence”.
Add following strings of new decoders to the parameter “code”: clover-2500,

sat-b-c-hsd and sat-mini-m-c-hsd.

8.7.0

05-March-2015

Add new modes: SAT-AERO-P, SAT-AERO-C, SAT-AERO-R and SAT-AERO-T.
Add new parameters: “acars-reassemble” and “acars-enable-ads-c”.
Add new parameters: “live-sound-mute” to turn on/off sound output to the

speaker.
New “CustomInput” element supporting the VITA-49 format.

Issues

Version

Date

Issue

All

7-Feb-2011

Incomplete un-installation of XML RCI SDK
Cause:

A windows background application is started if you start the RCI test
software. This software continues running even if the RCI test software

is stopped. Because of this the directory is still in use if you start a un-

installation of the XML RCI SDK and installation is incomplete.

Solution:

Restart your computer.

Run un-installation of the XML RCI SDK.

XML Messages

Scope

This section describes all XML messages used to interact with the WAVECOM Remote Control Interface
(RCI) and contains information from the DTD (Document Type Definition). The DTD file is available in the
XMLRCI installation folder.

Constraints

The values used in the description of the XML messages are only valid in the XML Remote Control Inter-
face context. In the context of the business logic of the WAVECOM decoders the values may be invalid.

Message categories

Messages are divided into five categories:

Category

Direction

Data type

Data

Server to client

Text, images, binary da-

ta, analysis data

Metadata

Server to client

Parameter information

Command

Client to server

Settings

Information

Server to client

Settings

Error

Server to client

Error messages

Data messages contain data derived from the captured signal, i.e., text, images, binary or analysis data.
Metadata messages return parameter values.
Command messages allow the client to control the behavior of the server and the decoder(s) it controls.