23 The static flushing device

SPS 100

SPS 100 pumps

Fitting the static flushing device

l The static flushing device can be fitted only to a SPS 100 pump with a pump

seal housing which is tapped to take it (arrowed). See also 22.2.2 Assembling
the SPS 100
.

l Pass the special L-shaped tool or a screwdriver through the top hole in the

bearing housing and use it to rotate the pump seal housing until it is central to
the top hole in the bearing housing.

l Fit the sight glass connection piece. Use a 17mm spanner to tighten it.
l Fit the sight glass.

The sight glass and the sight glass

connection piece

The tapped pump seal housing