beautypg.com

16 maintenance and repair, 15 limit values for the pump – Watson-Marlow SPS User Manual

Page 10

background image

MasoSine SPS sinusoidal pumps User Manual

10

7.16 Maintenance and repair

Inform operating personnel before starting maintenance and repair work. Protect all
plant parts and operating media connected before and after the machine, such as
compressed air and hydraulics, against unintentional start-up. In all maintenance,
inspection and repair work, switch the machine off and secure the main switch
against unintentional start-up.

Secure larger assemblies carefully to lifting gear. Check loosened screw connections
for firm seating. Use only original spare parts.

After maintenance work is finished, check the safety devices for
function.

7.15 Limit values for the pump

The pump’s maximum speed, maximum pressure and maximum temperature are
included in the technical data sheet supplied with each pump. These limit values
must not be exceeded in any circumstances. This applies in particular when using a
frequency converter.

If pump is supplied without a drive, the following values apply:

SPS 100 SPS 200 SPS 250 SPS 300 SPS 400 SPS 500

Maximum
pressure *

10 bar

10 bar

15 bar

15 bar

15 bar

15 bar

Maximum
speed *

1,000 rpm 1,000 rpm 800 rpm 600 rpm 600 rpm 600 rpm

Maximum
temperature *

100°C

100°C

100°C

100°C

100°C

100°C

Ambient
temperature

-12°C to

+40°C

-12°C to

+40°C

-12°C to

+40°C

-12°C to

+40°C

-12°C to

+40°C

-12°C to

+40°C

* These limits may be lower, depending on the drive, the application and the rating
of the pump. (See your purchase order confirmation, or contact MasoSine and give
your pump’s serial number.) On customer request, higher pressures are possible.