Watson-Marlow SPS User Manual
Page 37

MasoSine SPS sinusoidal pumps User Manual
37
21.2 Adjusting dimension X in models
with stainless steel power frame
Dimension X
Shim ring
Power frame
Bearing housing
Lip seals
Shaft
Bearing housing
retaining screw
Vernier
Dimension X
SPS 100
SPS 200
SPS 250
SPS 300
SPS 400
SPS 500
10.0mm
+0.05
17.5mm
+0.1
17.4mm
+0.1
23.0mm
+0.1
15.0mm
+0.1
25.4mm
+0.1
SPS 200, SPS 250, SPS 300, SPS 400 and SPS 500: adjusting
dimension X
Note: SPS 100 pumps must be returned to MasoSine for dimension X adjustment.
l Remove the front cover, the front support, the front liner, the rotor, the gate
and the gate guide. See 22 Dismantling and assembly.
l Measure dimension X.
l Check this dimension against the table above.
Power frame
Shim ring
Lip seals
Bearing housing
Bearing housing
retaining screw
Dimension X
Shaft
Vernier
- 323Dz (53 pages)
- 620SN (100 pages)
- Bredel 25 (76 pages)
- APEX35 (72 pages)
- Bredel 80 (76 pages)
- Bredel 15 (68 pages)
- 520Bp (107 pages)
- 323D (48 pages)
- EBU250 (8 pages)
- FF20 (24 pages)
- MR-Series (52 pages)
- GD30P (14 pages)
- EC 60 (28 pages)
- PetroProof Series (49 pages)
- Qdos30 Universal (40 pages)
- Qdos60 Universal 110V Logic (78 pages)
- 120F/DV (26 pages)
- 120S/DM3 (36 pages)
- SP50 (86 pages)
- 101U (14 pages)
- 505BA (21 pages)
- 700 series (11 pages)
- Qdos60 Profibus (66 pages)
- 521CC (47 pages)
- 401U (12 pages)
- 620RE4A (11 pages)
- 405U (13 pages)
- 624S (46 pages)
- Bredel 2100 (96 pages)
- Bredel 2100 (92 pages)
- 701 (25 pages)
- 840 (13 pages)
- 505LGA (11 pages)
- 620RE4 (19 pages)
- 205U (13 pages)
- 505U (19 pages)
- 704S (17 pages)
- 621 Trio (11 pages)
- 313T (16 pages)
- 624Di (37 pages)
- 505Di (39 pages)
- 501CC (17 pages)
- 504Du (31 pages)
- 504Du (30 pages)