Watson-Marlow SPS User Manual
Page 35

MasoSine SPS sinusoidal pumps User Manual
35
21 SPS 200, SPS 300 and SPS 400:
Adjusting the shaft
It is important that dimension X is correct to achieve efficient pumping.
Note: Dimension X in all pumps may be measured as below. However, the structure
of the SPS 100 pump casing is different from other models (and not as shown here)
and SPS 100 dimension X is adjusted differently. SPS 100 pumps must be returned
to MasoSine for dimension X adjustment.
21.1 Adjusting dimension X in models
with cast power frame
Dimension X
l Remove the front cover, the front support, the front liner, the rotor, the gate
and the gate guide. See 22 Dismantling and assembly.
l Measure dimension X.
l Check this dimension against the table above.
Shim ring
Dimension X
SPS 100
SPS 200
SPS 300
SPS 400
10.0mm +0.05
17.5mm +0.1
23.0mm +0.1
15.0mm +0.1
Power frame
Bearing housing
Leakage bore
SPS 200,
SPS 300,
SPS 400 pumps
Lip seals
Shaft
Bearing housing
retaining screw
SPS 200, SPS 300 and SPS 400: adjusting dimension X
Note: SPS 100 pumps must be returned to MasoSine for dimension X adjustment.