beautypg.com

Care and maintenance, Spares – Watson-Marlow 505Du User Manual

Page 23

background image

23

Care and maintenance

The only scheduled maintenance required for the 505Du/RL is inspection of the
motor brushes and their replacement before their length is less than 6mm (1/4").
The life of the brushes will depend on the duty of the pump, but is expected to be
at least 10,000 hours at maximum speed.

When the pump needs cleaning, remove the pumphead and use a mild solution
of detergent in water. Do not use strong solvents.

If the gearbox is rebuilt you must use the 15ml of the recommended lubricant,
which is Rocol MP, which is a SAE 30 mineral oil loaded with molybdenum
disulphide to form a soft fluid grease.

Spares

Transformer

Voltage selector switch

TF 0031

Tachometer disc assy

MN0787M

Display

MNA 0446A

ON/OFF Switch

SW 0147

SW 0086

Tachometer PCB

MNA0500A

Motor brush

BM 0014

9 pin socket
SL 0064

25 pin socket
SL 0058

Motor/gearbox

220 rpm MNA0388A

55 rpm MNA0396A

Panel
MN 0564B

Complete drive

220rpm 056.4841.000

55rpm 056.4821.000

Mains connector

US 0045

Mains fuse
FS 0003
(1.0A T)

ROM
MNA 0475A

Speed control PCB
(Excluding ROM)

PCB fuse
FS 0047
(2.0A T)

MNA 0507A

Audible alarm
MNA 0322A

Joint gasket

Vertical MN 0763S
Straight MN 0764S