INSTALLATION
21
•
Make sure that the maximum forces on the
flanges are not exceeded. The maximum flange
loads are given in the table below:
5.3.4
Pulsating flow
Hose pumps have a pulsating flow that can result in
vibrations of pump and flow lines under the following
circumstances:
•
suction and discharge lines are not fixed
correctly
•
high pump speed in combination with long
suction and discharge lines and/or high density
of the product
•
diameter of suction and/or discharge line too
small
In case of unacceptable pulsations, dampeners for
suction and/or discharge line can be supplied. Please
consult your Bredel representative for information on
Inlet Pulsation Accumulators (IPA) or Pulsation
Dampeners (PD). These accumulators and dampeners
are not suitable for food applications.
Force
Bredel CIP 40
Bredel CIP 50
F1 [N]
1000
1400
F2 [N]
200
300
F3 [N]
500
700