INSTALLATION

21

Make sure that the maximum forces on the
flanges are not exceeded. The maximum flange
loads are given in the table below:

5.3.4

Pulsating flow

Hose pumps have a pulsating flow that can result in
vibrations of pump and flow lines under the following
circumstances:

suction and discharge lines are not fixed
correctly

high pump speed in combination with long
suction and discharge lines and/or high density
of the product

diameter of suction and/or discharge line too
small

In case of unacceptable pulsations, dampeners for
suction and/or discharge line can be supplied. Please
consult your Bredel representative for information on
Inlet Pulsation Accumulators (IPA) or Pulsation
Dampeners (PD). These accumulators and dampeners
are not suitable for food applications.

Force

Bredel CIP 40

Bredel CIP 50

F1 [N]

1000

1400

F2 [N]

200

300

F3 [N]

500

700