Chapter 4. system commands, Operations in the zos, os/390, mvs environment – Visara FEP-4600 User Manual
Page 55

FEP-4600 Users Guide and Maintenance Manual
707118-001
4-1
Chapter 4. System Commands
In addition to managing resources directly from the FEP-4600, you will need to be
familiar with a variety of commands to manage some of the resources from a mainframe
console. Information is arranged by Host OS and connection type.
Operations in the zOS, OS/390, MVS Environment
ESCON CHPID Operations
Activating an ESCON CHPID:
You must issue this command from the Master Console for the LPAR. ‘xx’ represents the
CHPID number.
C F CHP(xx),ONLINE
Displaying Status of an ESCON CHPID:
This command can be used to display the status of the CHPID identified as ‘xx’.
D
M=CHP(xx)
Inactivating an ESCON CHPID:
This command is used to vary a CHPID offline. ‘xx’ represents the CHPID number.
C F CHP(xx),OFFLINE
ESCON PATH Operations
Activating an ESCON PATH:
This command is used to vary a path online. ‘yyyy’ represents the IODEVICE and ‘xx’
represents the CHPID.
V
PATH(yyyy,xx),ONLINE
Displaying an ESCON PATH:
This command can be used to display the current status of the ESCON paths included in
the identified CHPID. ‘xx’ represents the CHPID number.
D
M=CHP(xx)