22

C

HAPTER

3: F

RONT

P

ANEL

I

NTERFACE

The PRISM 4101 can not transmit alternating DSU loop code or cause sealing current
reversal to activate a loop on the remote end unit.

Remote Loop

The choices are On and Off.

This loop instructs the unit to transmit inband V.54

loop code to the remote end causing the remote unit to enter a V.54 loop. Refer to
the section entitled V.54 Loop on page 18 for specific information concerning the
V.54 loop.

BERT Function

The following menus offer selections for starting a BERT (Bit Error Rate Test)
along with test results.

BERT.

This selection turns the BERT to Off or On towards the Network (NET) or

towards the DTE.

Sync.

Displays the current state of pattern sync during a test. If no test is in

progress, then No Test is displayed.

Time.

Displays the elapsed time since a timed test began. A value is displayed

only when a test is running (in the HH:MM:SS format).

Bit Errors.

Displays the total number of bit errors detected since the test began or

since error statistics were last cleared.

Errored Seconds.

Displays the number of errored seconds that have been detected

since the test began or since error statistics were last cleared.

Sync Loss.

Displays the number of times during the test period that the BERT

pattern detector lost sync.

Reset.

When set to Yes, the BERT error counts and elapsed time values are

cleared to zero. This parameter then returns to No automatically.