beautypg.com

Unit ip address, Router ip address, Subnet mask – Verilink PRISM 4101 (34-00230) Product Manual User Manual

Page 31: Filter ip address, Trap ip address, Sets, Read community, Unit ip address router ip address subnet mask

background image

Main Menu

19

The SNMP menu consists of alpha-numeric entry only (no selectable parameters).
The following three menu items use the format shown in the IP Address screen.
Each number has a range from 0 to 255 and is separated by a period.

Figure 3-12 Example IP Address

Unit IP Address

Accepts IP addresses. Each device connected to the LAN is required to have a
unique IP address identifier.

Router IP Address

Accepts the IP address of a default router, if one is present.

Subnet Mask

Provided to manually override the subnet mask setting which is otherwise
discovered by the SNMP agent.

Filter IP Address

Accept the IP address of the source packet filter. If any of these fields are set,
access is allowed only by the specified IP addresses.

Trap IP Address

Accepts the IP address of a network device where alarm reporting traps are to be
sent. The unit detects and reports alarms and provides several options for reporting
them, one of which is SNMP traps. When a network alarm occurs, the unit sends a
trap message to up to six destinations on the user’s network.

Sets

Enables or disables the SET commands. If this field is set to No, the SNMP
manager wil be unable to change the unit’s configuration. Refer to Appendix A for
detailed information on these responses.

The following five menu items use the format shown in the System Edit screen.
The top line in each screen accepts a string of up to 58 characters which identifies
the appropriate group, person, device function, or unit location.

Figure 3-13 System Edit

Read Community

Accepts a character string identifying the group authorized to perform read
operations. The default setting is public.

>

132.016.232.000

Read Community

>public