Features -2 specifications -2, Network interface -2 equipment interface -2, Features – Verilink 2000 (34-00182) Product Manual User Manual
Page 6: Specifications

1-2
G
ENERAL
Features
✦
Stand-alone or nest mounting
✦
D4-to-D4, D4-to-ESF, ESF-to-D4, or ESF-to-ESF framing
✦
AMI or B8ZS line coding or AMI to B8ZS conversion
✦
Front panel test access jacks
✦
RS-232 supervisory and network manager ports
✦
Separate user and telco performance registers with a 30 -day history
✦
User and telco access via the ESF facility data link
✦
BERT with multiple patterns and selectable looping tests
✦
End-to -end user control and access to unit performance data, unit configuration,
and unit status (normal, looped, and alarm)
✦
Optional EM8000 Element Manager and 8100A Site Controller
✦
Programmable threshold alarms with audible output to indicate a local alarm condition
✦
Full ALBO levels (telco) and DSX levels (user)
✦
Field software upgrades (Flash PROM memory)
✦
Battery-backed RAM configuration storage
Specifications
Network
Interface
Line Rate:
1.544 Mbps,
±
50 bps for internal clock,
±
200 bps in
through mode
Line Framing:
D4 or ESF
Line Code:
AMI or B8ZS
Line Impedance:
balanced 100
Ω
(
±
5%)
Input Signal:
DS1, 0 to -27 dB (ALBO)
Output Signal:
3.0 V (
±
15%), base-peak into 100
Ω
Line Build Out:
0, -7.5, -15, and -22.5 dB attenuation
Line Protection:
1000 V lightning, fused inputand output
Jitter Control:
per TR62411 and T1.403
Pulse Density:
per TR62411
Equipment
Interface
Line Rate:
1.544 Mbps,
±
50 bps for internal clock,
±
200 bps in
through mode
Line Framing:
D4 or ESF
Line Code:
AMI or B8ZS
Line Impedance:
balanced 100
Ω
(
±
5%)
Input Signal:
DSX1 to -6 dB