Utilities screen -19, Utilities screen – Verilink 2000 (34-00182) Product Manual User Manual
Page 53
Utilities Screen
4-19
Unavailable Seconds
A one-second period in which consecutive severely errored seconds cause an
unavailable state.
DTE LOS/LOF Seconds
A one-second period in which the T1 received signal (on the CSU’s DTE side) is
interrupted or the amplitude drops below a certain level.
Remote Alarm Seconds
Generated by the terminal equipment when an improper signal is received from the
facility (or upon receipt of unframed all ones).
AIS Seconds
A one-second period in which all ones are received.
Out of Frame Seconds
A one-second period in which a frame sync loss occurred.
BPV Seconds
A one-second period in which at least one bipolar violation occurred.
Alarm Reset Timer
Determines the number of seconds after alarm conditions clear before indications
are removed.
Go to Line Settings
Pressing Enter here brings up the Line Configuration screen.
Utilities
Screen
The Utilities screen (Figure 4-16) handles the functions described in the following
paragraphs.
2000 CSU x.xx/x.xx
2000 CSU Date
MM/DD/YY
2000 CSU x.xx/x.xx
(Unit Address: xxx)
Time HH:MM:SS
---------------------------------- UTILITIES
-----------------------------------
Element: [NEAR]
Set Time:
(14:10:13)
Set Date:
(05/12/93)
Alarm Notification:
[DIAL ]
Primary Phone#:
(1 (205) 555-1212 )
Secondary Phone#:
(9,,532-8853,,253 )
Element ID:
(Example CSU 2000 )
New Password:
()
(MAINTENANCE RESET)
Figure 4-16 Utilities Screen