Unit Configuration

2-7

Supervisory Port Bit Rate

Positions S4 -5 and S4-6 are used to set the supervisory port bit rate. This is a
serial RS-232 DCE port configured for 8 bits, no parity, and 1 stop bit. Table 2-5
shows the available speeds.

NMS Bit Rate

Positions S4 -7 and S4-8 are used to set the NMS port bit rate. This is a serial
RS-232 DCE port configured for 8 bits, no parity, and 1 stop bit. Table 2-6 shows
the available speeds.

Configuration

Switch S5

Switch S5 (Figure 2-4) is used to set the configuration parameters listed in the
following paragraphs.

Network Line Framing

Position S5-1 is used to match the CSU to the framing of the network line.

Down: ESF Up: D4

Table 2-5 SUPV Port Bit Rate

S4-5

S4-6

SUPV Port Bit Rate

Dn

Dn

19200 bps

Dn

Up

9600 bps

Up

Dn

2400 bps

Up

Up

1200 bps

Table 2-6 NMS Port Bit Rate

S4-7

S4-8

NMS Port Bit Rate

Dn

Dn

19200 bps

Dn

Up

9600 bps

Up

Dn

2400 bps

Up

Up

1200 bps

7

6

5

4

3

2

1

8

Dn

Up

Netw

o

rk

D4

DTE

D4

Netw

o

rk

DTE

AIS

Ke

e

p

A

liv

e

CRC

FD

L

B8

ZS

B8

ZS

Fr

a

m

ed

Lo

op

ed

Pa

ss

Pa

ss

FD

L

T

e

rmin

ate

Ne

tw

ork

ES

F

CRC

K

eep

Al

iv

e

AIS

DT

E

Ne

tw

ork

DT

E

ES

F

AM

I

AM

I

Un

fra

med

AIS

Re

g

en

erate

Figure 2-4 Switch S5