Pattern sync -14 elapsed time -14 bit errors -14, Errored seconds -14 % efs -14, Line fault and loop status -14 – Verilink 2000 (34-00182) Product Manual User Manual
Page 48: Net/dte status -14 near loops -14 far loops -14

4-14
T
ERMINAL
O
PERATION
Pattern Sync
This field displays the current state of pattern sync during a test. If no test is in
progress, NO TEST is displayed. If a test is active, but the receiver is not in
pattern sync, NO SYNC is displayed. If the receiver is in pattern sync, IN SYNC
is displayed.
Elapsed Time
Displays the amount of time elapsed since a timed test began or, if completed, the
total test time.
Bit Errors
Displays the total number of bit errors detected since the test began or since error
statistics were cleared (up to a maximum number of 999,999).
Errored Seconds
This field displays the number of asynchronous errored seconds that have been
detected since the test began or since error statistics were last cleared. This
parameter includes errored seconds and sync loss seconds.
% EFS
This ratio is derived from the number of error free seconds divided by the number
of seconds accumulated in Elapsed Time.
Line Fault
and
Loop Status
NET/DTE Status
These two fields display the fault status of the network and the DTE. They are
indicators of current fault conditions. They do not indicate that alarm thresholds
have been exceeded. These status indications are described in Table 4-3.
Near Loops
Displays the loop status of the near element.
Far Loops
Displays the loop status of the far element.
Table 4-3 Status Indications
Status
Description
-------
No status is available.
OK
No errors are currently detected.
ERR
Frame bit errors, CRC errors, or bipolar violations are detected.
LOS
A loss of signal condition exists.
OOF
An out of frame condition exists.
RAI
A remote alarm indication signal is being received from the far end.
AIS
An alarm indication signal is being received from the far end.
UAS
An unavailable signal state exists due to consecutive severely errored seconds.