25

Triplett Model 9320-A

FIGURE 6

MEASURING AC AMPS

If it is desired to hold the reading, press the D-HOLD button so that the

annunciator is visible on the display.

WARNING!!!

WHENEVER TOUCHING THE METER IN AN ENERGIZED CIRCUIT, THE USE

OF A LINEMAN’S GLOVE CONFORMING TO ASTM D120, IS REQUIRED.

Remove the Meter from the circuit by opening the Jaws and carefully withdrawing
it.

Notes:
1)
Although the Auto annunciator displays on the 400A

range, there is only

one range on this setting, i.e. 400A.

2) Although the Hz/Duty button appears to function in the 400A~ and 1000A~
ranges, this feature is not available.