Triplett 9320-A User Manual
Page 15

14
Triplett Model 9320-A
11) D. HOLD / LIGHT Button – Holds the reading in the display when the D-HOLD
button is pressed and released.
appears in the display to indicate that the
D.HOLD is activated. To release, press the D.HOLD Button again. To turn on
the LCD backlight, press and hold the button for 2 seconds or longer. To turn
the backlight off, again press and hold the button for 2 seconds or longer.
12) Hand Guard – Grasp meter below this guard. Do not touch any bare
conductors that the jaws may be clamped around.
13) Clamp (Jaws) – Opens 1.25” (32MM) to enclose conductor(s).
FIGURE 2
DISPLAY DETAILS
Refer to Figure 2 to identify the various display annunciators.
AUTO
The Auto (ranging) annunciator is on when the meter is set to a
function that has multiple ranges available. The meter is completely
automatic and does not require the user to select a range.
The AC
~
annunciator is on when the meter is set to measure AC
voltage or current.
Negative Sign Annunciator – This annunciator is displayed when DC
voltage is measured by the V
Ω
Hz jack is negative with respect to the
COM jack. It can also be displayed in the A
mode, when the
measured current is reversed to the direction of the polarity arrow.
Note: Polarity arrow indicates current flow from positive to negative.
+
_
Low Battery Annunciator – This annunciator is displayed when the
battery needs to be replaced.